Water purifiers

Filter and sort 3 products
Sort by

A laboratory water purifier is essential equipment for any demanding analytical environment. It produces pure, demineralized, or ultrapure water, suitable for reagent preparation, sensitive protocols, and feeding analytical instruments. The quality of the water used directly determines the reliability of the results obtained.


At Rewake, every water purifier is refurbished, inspected, and tested by our technicians before shipment. You receive professional, operational, and guaranteed equipment, ready to be integrated into your laboratory without delay and without compromising on the quality of the water produced.


This collection is aimed at research laboratories, pharmaceutical teams, chemical analysis units, and any professional in need of reliable and reproducible filtration at a controlled cost.

En savoir plus

What is a laboratory water purifier?

A laboratory water purifier is a piece of equipment designed to remove impurities, contaminants, heavy metals, ions, microorganisms, and organic residues present in feedwater. It produces water suitable for analytical requirements, with a purity level defined by standardized grades: type 3 for general use, type 2 for reagent preparation, and type 1 ultra-pure for the most sensitive applications.

The processes implemented vary according to the target grade. Reverse osmosis retains ions and dissolved salts by applying pressure to a semi-permeable membrane. Activated carbon filtration removes chlorine, pesticides, and organic residues. Deionization via ion-exchange resins produces high-resistivity water. UV lamps destroy residual microorganisms.

These units are fundamentally different from domestic purifiers, which are designed solely to improve the quality of drinking water. A laboratory purifier meets precise analytical specifications, with continuous monitoring of resistivity and microbiological contamination.

The different types of water purifiers available

The Rewake collection covers the main families of water purifiers used in laboratories. Each type meets specific requirements regarding purity, flow rate, and feedwater compatibility. Identifying the right model from the start prevents selection errors and adaptation costs.

The available systems range from reverse osmosis purifiers for the production of grade 2 or 3 water, to combined systems producing type 1 ultra-pure water for the most demanding analytical applications. The type of cartridges required and the resistivity of the produced water are the two priority criteria to evaluate.

Reverse osmosis purifier

The reverse osmosis purifier is the benchmark for the production of quality demineralized water in a laboratory. Pressure is applied to a semi-permeable membrane that retains ions, salts, heavy metals, sediments, and dissolved pollutants, while allowing water molecules to pass through.

This type of equipment is suitable for preparing buffers, aqueous solutions, and supplying analytical instruments that require grade 2 or 3 water. Installation constraints include a minimum feed pressure, an upstream pre-filter to protect the membrane, and management of the rejection rate based on the quality of the input water.

Deionization purifier and combined system

The deionization purifier uses ion-exchange resins to capture residual cations and anions and produce high-resistivity water. This process is often used downstream of an osmosis unit to refine the purity of the produced water.

Combined systems associate reverse osmosis, resins, a UV lamp, and ultrafiltration to produce type 1 ultra-pure water, which is essential for HPLC, molecular biology, and cell culture. The resistivity of the produced water, expressed in MΩ.cm, is the key parameter that determines the suitability of the equipment for the intended application.

Technical criteria for choosing your laboratory water purifier

The first criterion is the water grade required by laboratory protocols. Equipment producing type 2 water is not suitable for applications requiring type 1 ultra-pure water. The resistivity of the produced water, expressed in MΩ.cm, is the reference parameter for evaluating the actual purity of the equipment.

The quality of the feedwater directly influences the choice of the filtration system. Tap water loaded with limescale, chlorine, or sediments requires a suitable upstream pre-filter to protect membranes and resins. Local water hardness should be measured before selecting any equipment.

The flow rate in liters per hour must be adapted to the actual needs of the laboratory. An undersized flow rate creates bottlenecks in protocols, while an oversized model generates unnecessary operating costs. The presence of a UV lamp is essential for applications requiring microorganism-free water.

The frequency of cartridge replacement, the equipment's footprint, and its compatibility with the existing hydraulic installation are practical criteria to verify before acquisition. The long-term availability of replacement consumables is also a point not to be overlooked.

Rewake refurbished water purifiers: our reconditioning process

Each water purifier included in the Rewake collection follows a structured reconditioning protocol, performed by technicians specializing in laboratory equipment. The objective is to restore performance levels consistent with original specifications at a reduced acquisition cost.

The first step is a complete inspection of the housing and hydraulic circuits. The condition of connections, valves, hoses, and seals is checked to detect any leaks, corrosion, or obstructions. Filter cartridges and membranes are checked and replaced if necessary before performance testing.

The pump and solenoid valves are tested under real operating conditions. The resistivity of the produced water is measured and compared to the equipment's original specifications. A deviation outside of tolerance leads to the replacement of the relevant resins or membrane.

A complete disinfection of the internal hydraulic circuit is performed systematically before shipment to ensure water free from microbiological contamination from the very first use. Each piece of equipment comes with a warranty and full traceability, including the resistivity values measured during validation tests.

For which uses and sectors?

The water purifiers in the Rewake collection cover a wide spectrum of professional applications. In HPLC and analytical chromatography, type 1 ultra-pure water is essential for preparing mobile phases and dissolving standards. Insufficiently purified water introduces interferences that compromise the quality of the analyses.

In molecular biology and PCR, water used for the preparation of reagents and buffers must be free of ions, microorganisms, and traces of contaminating DNA or RNA. The water purifier is a critical piece of equipment here for the reproducibility of results.

Cell culture, microbiology, and the preparation of pharmaceutical reagents require water of constant and traceable quality. Supplying autoclaves with demineralized water extends their lifespan and prevents the scaling of heating elements and steam circuits.

The pharmaceutical industry uses this equipment for the production of purified water in compliance with pharmacopoeia requirements. Environmental and food analysis laboratories also rely on these systems to ensure the reliability of their measurements on complex matrices.

Why choose a refurbished water purifier?

The main argument is economic. A refurbished water purifier is available at a price significantly lower than that of equivalent new equipment. For laboratories managing tight budgets or equipping several stations simultaneously, this is a concrete way to reduce costs without compromising on the quality of the produced water.

Major brands of laboratory water purification are represented in the Rewake collection. Accessing systems recognized for their reliability and processing precision at a controlled cost is a direct advantage for teams subject to strict analytical requirements.

Delivery times are generally shorter than for new orders, as the equipment is available in stock and ready to ship. An urgent replacement or a rapid expansion of pure water production capacity thus becomes possible without waiting weeks for supply.

Environmentally, extending the lifespan of laboratory equipment reduces manufacturing needs and limits electronic and plastic waste. Reconditioning contributes to reducing overall water consumption linked to the manufacturing of new equipment, without harming the operational quality of the delivered equipment.

Request a quote for a laboratory water purifier

Are you looking for a water production solution adapted to your analyses and preparations? Rewake offers refurbished laboratory water purifiers. Request your quote based on the required water quality, flow rate, and storage capacity.

FAQ — Refurbished water purifier

What is the difference between a laboratory water purifier and a domestic purifier?

A domestic purifier improves the taste of drinking water and reduces limescale, without guaranteeing a level of analytical purity. A laboratory purifier produces water of high chemical and microbiological purity, with controlled and traceable resistivity. These two types of equipment meet radically different requirements and are not interchangeable, regardless of the quality of the available feedwater.

How do I choose the right water grade for my application?

Type 3 water is suitable for glassware washing and common, less sensitive applications. Type 2 water is suitable for the preparation of reagents and routine analyses. Type 1 ultra-pure water is essential for HPLC, molecular biology, and cell culture. The grade required by your protocols must be identified before selecting any equipment, as it directly dictates the type of purifier needed.

Do Rewake refurbished water purifiers produce water compliant with analytical requirements?

Every purifier is tested for the actual resistivity of the water produced before shipment. Cartridges, membranes, and UV lamps are checked and replaced if necessary. The values measured during testing are compared to the equipment's original specifications. Test reports are available upon request for accredited laboratories or those subject to quality audits.

What is the replacement frequency for laboratory water purifier cartridges?

The frequency depends on the quality of the feedwater, the daily production volume, and the type of cartridge. Pre-filters are replaced more often than reverse osmosis resins or membranes. Regular monitoring of the resistivity of the produced water is the best indicator for anticipating the replacement of consumables before any degradation of quality occurs.

What maintenance is required for a laboratory water purifier?

Regular maintenance focuses on five points: replacing filter cartridges according to production volume, periodic checks of resistivity, disinfection of the hydraulic circuit, verification of the UV lamp, and cleaning of valves and connections. Rigorous maintenance is essential to maintain the quality of the produced water and extend the equipment's lifespan.

Our commitments

Equipment checked

All the equipment we sell has been reconditioned and checked by our teams.

Delivery and installation

We offer delivery throughout mainland France as well as on-site installation if necessary.

Guarantee

All equipment is guaranteed for at least 6 months after purchase, or even longer depending on conditions.