What is a laboratory fume hood?
A chemical fume hood, also known as a fume cupboard, is a ventilated workstation designed to extract toxic vapors, fumes, and gases produced during chemical handling. It protects the operator by creating a continuous airflow that captures pollutants at the source, before they can disperse into the workspace.
Its operating principle is based on frontal suction: air is drawn in through the front opening of the hood, passes through the work area, and is either exhausted to the outside via a duct or filtered internally before being released back into the ambient air.
A chemical fume hood should not be confused with a microbiological safety cabinet or a laminar flow hood. These two types of equipment are designed to protect the product or sample, not the operator. The air velocity at the front opening is the key parameter that determines the actual effectiveness of a chemical fume hood.
The different types of chemical fume hoods available
The Rewake collection covers the main families of chemical fume hoods used in laboratories. Each type meets specific installation constraints and risk levels. Identifying the right model from the start prevents poor choices and costly retrofitting.
Benchtop hoods are the most common: they are installed on an existing workbench and are suitable for the majority of standard chemical procedures. Suspended models are designed for spaces where the workspace is limited or shared.
Ducted fume hood
The ducted fume hood is the gold standard for laboratories handling volatile or highly toxic products. The captured vapors and fumes are expelled directly to the outside via a duct, thanks to a high-performance extraction system, with no release into the laboratory's ambient air.
This type of hood requires a connection to an exhaust duct and an appropriate ventilation system (VMC). Ceiling height and room configuration must be taken into account before installation. It is the solution that offers the highest level of safety for extracting air laden with chemical pollutants.
Ductless (recirculating) fume hood with carbon filter
The recirculating hood operates in a closed circuit: the air drawn in is filtered internally by an activated carbon filter and then released into the laboratory's ambient air. It requires no ducting or external connections, which simplifies installation and reduces implementation costs.
This recycling mode is suitable for light solvents and odors but has limitations for aggressive chemicals or high concentrations. The carbon filter must be replaced regularly based on the frequency of use to prevent saturation. A HEPA filter can be added as a supplement to capture fine particles.
Technical criteria for choosing the right chemical fume hood
The first criterion to evaluate is the airflow rate, expressed in m³/h. It determines the hood's capacity to renew and exhaust contaminated air from the work area. An insufficient flow rate directly compromises operator protection.
The air velocity at the front opening is governed by the NF EN 14175 standard. A minimum value of 0.5 m/s is generally required to ensure effective vapor containment. This parameter is verified during the reconditioning of every Rewake hood.
The usable width of the workspace determines the volume of procedures that can be carried out simultaneously. The materials of the internal chamber and casing, made of stainless steel, guarantee resistance to corrosive products and facilitate cleaning.
Noise level, expressed in decibels, is a criterion often overlooked in a professional environment. A hood that is too noisy hinders work comfort during long sessions. Integrated LED lighting improves visibility on the work area without generating excessive heat. The type of filter chosen, activated carbon or HEPA, must match the products actually being handled.
Rewake reconditioned chemical fume hoods: our refurbishment process
Each chemical fume hood included in the Rewake collection goes through a structured reconditioning protocol carried out by specialized technicians. The goal is to guarantee performance identical to that of new equipment, at a reduced acquisition cost.
The first step is a complete structural inspection: condition of the casing, the sash, the stainless steel walls, and the controls. Any part showing wear or degradation is replaced before testing.
The suction system is then checked in detail: inspection of the fan, measurement of actual airflow, and verification of velocities at the front opening. These values are compared to the equipment's original specifications.
Filters are checked and replaced if necessary. The lighting, speed controllers, and all controls are tested under real-world conditions. Every shipped hood comes with a warranty and full traceability, so you have reliable equipment ready for service.
For what uses and sectors?
Chemical fume hoods from the Rewake collection cover a wide spectrum of professional applications. They are used in academic research laboratories, pharmaceutical production units, quality control departments, and industrial analysis laboratories.
In cleanrooms, they allow work under chemical protection while limiting the risks of cross-contamination. For PCR protocols and sensitive biological procedures, they constitute a first line of protection for the operator, as a complement to a microbiological safety cabinet.
Operations involving the weighing of toxic powders or the preparation of concentrated solutions are among the most common uses. In these situations, containing dust and vapors at the source is essential to secure the work area.
The fine chemical, petrochemical, and environmental sectors also rely on this equipment for daily handling of toxic or volatile products. The Rewake range helps meet these needs without long supply delays.
Why choose a reconditioned chemical fume hood instead of a new one?
The main advantage of reconditioned equipment is economic. A reconditioned laboratory chemical fume hood is available at a significantly lower price than equivalent new equipment, with no compromise on performance or safety. It is a concrete way to optimize a laboratory's equipment budget.
The major brands in the sector are represented in the Rewake collection. Accessing equipment recognized for its reliability, at a controlled cost, is a direct advantage for teams that have precise technical requirements without unlimited budgets.
Delivery times are generally shorter than for new orders, as the equipment is available in stock and ready to ship. This is a decisive point when an urgent replacement is required in an active laboratory.
Environmentally, extending the life of laboratory equipment reduces manufacturing needs and limits industrial waste. Reconditioning is part of an approach to energy efficiency and concrete responsibility, without detracting from the operational quality of the delivered equipment.
Request a quote for a laboratory chemical fume hood
For your chemical handling procedures and applications requiring adapted suction, discover our reconditioned chemical fume hoods. Request your quote for a laboratory chemical fume hood based on your environment and technical constraints.
FAQ — Reconditioned chemical fume hood
What is the difference between a chemical fume hood and a laminar flow hood?
The chemical fume hood, or fume cupboard, is designed to protect the operator. It draws in toxic vapors and fumes generated during handling and exhausts them to the outside or filters them internally. The laminar flow hood works in the opposite way: it blows filtered air over the work area to protect the sample or product, not the operator. These two pieces of equipment serve distinct needs and are not interchangeable.
How do I choose the right chemical fume hood for my laboratory?
The choice depends on several parameters: the nature of the products handled, the required airflow, installation constraints (external exhaust or recycling), the available workspace width, and the acceptable noise level. For complex configurations or specific needs, the Rewake team is available to guide you toward the most suitable model.
Do Rewake reconditioned chemical fume hoods comply with current standards?
Each hood is tested for suction performance and air velocity at the front opening, in accordance with the requirements of the NF EN 14175 standard. Test reports are available upon request. Rewake reconditioning aims to restore performance in line with the original specifications of each piece of equipment.
Is an exhaust duct mandatory to install a chemical fume hood?
No. Ducted models require a duct and a connection to the outside. Recirculating models operate in a closed circuit with an activated carbon filter, with no duct required. However, the latter have limitations for highly volatile or aggressive chemicals, for which external exhaust remains the safest solution.
What maintenance is required for a laboratory chemical fume hood?
Regular maintenance focuses on three main points: replacing carbon filters according to frequency of use and saturation levels, cleaning the stainless steel work surface, and periodically verifying the airflow and fan. Rigorous maintenance is essential to maintain filtration efficiency and ensure operator safety over time.