PCR fume hoods
A PCR hood is a ventilated workstation essential in any laboratory performing polymerase chain reactions. It protects preparations against cross-contamination by DNA, RNA, and aerosols by maintaining a sterile atmosphere and filtered airflow over the handling area.
At Rewake, every PCR hood is refurbished, inspected, and tested by our technicians before shipment. You receive operational, professional equipment, under warranty, ready to be integrated into your molecular biology or microbiology laboratory without delay.
This collection is aimed at research teams, diagnostic laboratories, pharmaceutical units, and any professional needing reliable protection against contamination of their PCR preparations at a controlled cost.
En savoir plus
What is a laboratory PCR hood?
A PCR hood is a laminar flow ventilated workstation designed to protect PCR preparations from cross-contamination. It generates a unidirectional filtered airflow that removes suspended particles, microorganisms, and residual traces of DNA or RNA from the handling area, thereby ensuring the sterility of prepared reactions.
Its operating principle relies on air filtration via a high-efficiency HEPA filter, which traps particles down to 0.3 microns. An integrated UV lamp allows for the decontamination of the work surface between handling sessions by destroying residual nucleic acids that could potentially skew results.
A PCR hood differs from a microbiological safety cabinet, which simultaneously protects the product, the operator, and the environment. It also differs from a chemical fume hood, whose role is to extract toxic vapors to protect the operator. The stainless steel work surface facilitates cleaning and is resistant to common decontamination products.
The different types of PCR hoods available
The Rewake collection covers the main families of PCR hoods used in laboratories. Each type meets specific application constraints, protection levels, and installation configurations. Identifying the right model from the start prevents contamination risks and adaptation costs.
The available equipment ranges from compact benchtop hoods for space-constrained laboratories to microbiological safety cabinets for handling pathogens. The type of hood selected must precisely correspond to the level of protection required by the laboratory's protocols.
Vertical laminar flow PCR hood
The vertical laminar flow hood is the standard for protecting PCR preparations. Air filtered through a HEPA filter descends vertically over the work area, creating a unidirectional flow that sweeps particles and microorganisms toward the periphery of the work surface without turbulence.
It is used for the preparation of PCR reactions, cell culture, and any handling requiring a controlled atmosphere free from particulate contamination. Air velocity at the work surface and the efficiency of the HEPA filter are the two most important technical parameters to verify when selecting a model.
Horizontal laminar flow PCR hood and recirculating hood
The horizontal laminar flow hood blows filtered air horizontally toward the operator, which ensures optimal protection for the product but offers no protection for the operator. It is suitable for handling non-hazardous products that require a perfectly clean work area, such as certain sterile preparations or the handling of sensitive components.
The recirculating hood filters air in a closed loop through a HEPA filter and an activated carbon filter before releasing it back into the ambient air. It requires no connection to external ventilation, which simplifies installation. The main point of vigilance is the gradual saturation of the filters, which requires regular monitoring and replacement based on usage frequency.
Technical criteria for choosing your PCR hood
The first criterion is the flow type: vertical or horizontal. A vertical flow is preferable for the majority of PCR preparations because it creates a downward air barrier that effectively protects the work surface without directing air toward the operator. Horizontal flow is suitable for applications where product protection is more critical than operator protection.
HEPA filter efficiency and airflow velocity at the front opening are the two central analytical parameters. The presence of a UV lamp is essential for laboratories subject to strict decontamination protocols between each PCR series. Noise level is an important practical criterion for workstations in shared environments.
The dimensions of the work surface and the available work volume must be adapted to the formats of tubes, plates, and equipment used. The presence of airflow drift alarms allows for the detection of any functional anomalies before they affect the quality of the preparations.
Compliance with applicable NF EN ISO standards, the type of extraction selected (recirculation or external), and the availability of replacement filters complete the evaluation. For accredited laboratories, the traceability of filter integrity tests is a point to validate prior to acquisition.
Rewake refurbished PCR hoods: our reconditioning process
Each PCR hood in the Rewake collection follows a structured reconditioning protocol, carried out by technicians specialized in laboratory equipment. The objective is to restore filtration and protection performance to meet original specifications, at a reduced acquisition cost.
The first step is a complete inspection of the cabinet and the stainless steel work surface. The condition of the interior walls, seals, and filter mounts is checked to detect any air leaks that could compromise the efficiency of the laminar flow. Any anomaly detected is corrected before performance testing.
The fan is checked across its entire speed range. The actual airflow is measured and compared to the original specifications. The integrity of the HEPA filter is tested to detect any perforation or separation that could allow particles to pass through. Any filter whose integrity is not confirmed is systematically replaced.
The UV lamp is checked and replaced if its intensity is insufficient. Alarms and controls are tested under real conditions. Each PCR hood shipped comes with a warranty and full traceability, including the airflow values measured during validation tests.
For which uses and sectors?
PCR hoods from the Rewake collection cover a wide spectrum of professional applications. In molecular biology, they are used daily for the preparation of PCR reactions, the handling of DNA and RNA templates, and the setup of negative controls, which require a work area free from any trace of contaminating nucleic acids.
In microbiology and bacteriology, they protect sterile culture media preparations and the handling of sensitive biological samples. Cell culture also uses this equipment to maintain a controlled atmosphere during subculturing and cellular treatments.
The pharmaceutical industry and biotechnology firms use PCR hoods for the preparation of sterile reagents, the weighing of powders sensitive to particulate contamination, and the quality control of biological raw materials. Cleanrooms and demanding ISO environments are among the usage contexts covered by the Rewake range.
Medical diagnostics and fundamental research round out the spectrum of applications. In these environments, the reproducibility of PCR results depends directly on the quality of protection offered by the workstation used for preparations.
Why choose a refurbished PCR hood?
The main argument is economic. A refurbished PCR hood is available at a price significantly lower than that of equivalent new equipment. For laboratories managing tight budgets or equipping multiple PCR preparation stations simultaneously, it is a concrete lever for cost reduction without compromising on contamination protection.
Major brands in laboratory protection are represented in the Rewake collection. Accessing hoods known for their reliability and filtration efficiency, at a controlled cost, is a direct advantage for teams subject to strict reproducibility requirements.
Delivery times are generally shorter than for new orders, as equipment is available in stock and ready to ship. An urgent replacement after a breakdown or a rapid expansion of PCR preparation capacity thus becomes possible without tying up a large investment budget.
Environmentally, extending the lifespan of a laboratory hood reduces manufacturing requirements and limits industrial waste. Reconditioning contributes to a better overall air quality in the laboratory by keeping high-performance filtration equipment in service, without impairing its operational effectiveness.
Request a quote for a laboratory PCR hood
To protect your PCR preparations from contamination, Rewake offers refurbished PCR hoods adapted for molecular biology applications. Request your quote for a laboratory PCR hood according to your needs and your available space.
FAQ — Refurbished PCR hood
What is the difference between a PCR hood and a microbiological safety cabinet?
A laminar flow PCR hood is designed to protect the product against external cross-contamination. The filtered air creates a barrier that prevents particles and nucleic acids from contaminating the preparations, but it does not protect the operator from the biological agents being handled. A microbiological safety cabinet provides simultaneous protection for the product, the operator, and the environment. For handling pathogens, only a microbiological safety cabinet of the appropriate class is suitable.
How does the UV decontamination of a PCR hood work?
UV decontamination relies on the emission of radiation at 254 nm, which destroys residual nucleic acids (DNA and RNA) present on exposed surfaces, limiting the risks of false positives between PCR series. The UV lamp does not replace manual surface cleaning with a suitable decontamination product. Its effectiveness decreases with the aging of the lamp, which is why Rewake checks and replaces the UV lamp if necessary during each reconditioning.
Are Rewake refurbished PCR hoods compliant with current standards?
Each hood is tested for its actual airflow, HEPA filter integrity, and UV lamp operation before shipment. Performance is compared to the equipment's original specifications and the requirements of NF EN ISO standards applicable to laminar flow hoods. Test reports are available upon request for laboratories that are accredited or subject to quality audits.
Is external ventilation required for a PCR hood?
Recirculating PCR hoods do not require any connection to the outside: the air is filtered through a HEPA filter and an activated carbon filter before being released into the ambient laboratory air. Models with external extraction are preferable for handling processes that generate vapors or aerosols. Installing a recirculating model is simpler but requires regular monitoring of filter saturation to ensure protection effectiveness.
What maintenance is required for a laboratory PCR hood?
Regular maintenance involves four points: decontamination of the stainless steel work surface after each use, periodic verification of airflow and air velocity at the front opening, replacement of HEPA and carbon filters based on their saturation level, and verification of the UV lamp intensity. Rigorous maintenance is essential to maintain protection against microbial contamination and to ensure the reproducibility of PCR results.
Our commitments
Equipment checked
All the equipment we sell has been reconditioned and checked by our teams.
Delivery and installation
We offer delivery throughout mainland France as well as on-site installation if necessary.
Guarantee
All equipment is guaranteed for at least 6 months after purchase, or even longer depending on conditions.